This paper presents experimental measurements of beaching times for buoyant microplastic particles released, both in the pre-breaking region and within the surf zone. The beaching times are used to quantify cross-shore Lagrangian transport velocities of the microplastics. Prior to breaking the particles travel onshore with a velocity close to the Lagrangian fluid particle velocity, regardless of particle characteristics. In the surf zone the Lagrangian velocities of the microplastics increase and become closer to the wave celerity. Furthermore, it is demonstrated that particles having low Dean numbers (dimensionless fall velocity) are transported at higher mean velocities, as they have a larger tendency to be at the free-surface relative to particles with higher Dean numbers. An empirical relation is formulated for predicting the cross-shore Lagrangian transport velocities of buoyant microplastic particles, valid for both non-breaking and breaking irregular waves. The expression matches the present experiments well, in addition to two prior studies.
From the process control point of view, any reliable and online Oil-in-Water (OiW) measurement could provoke a brand new control paradigm for produced water treatment. However, the real-time OiW monitoring is still an open and ad-hoc situation in recent decades. The fundamental issue, ie, the OiW measurement is methodology dependent, leads to numerous challenges, such as (i) how to verify the reliability and accuracy of a specific methodology/instrument; (ii) how to handle and interpret the measured data in a most objective manner; and (iii) how to keep a cost-effective on-site calibration and maintenance under the harsh offshore conditions etc. The paper reports our latest achievements and observations in usage of fluorescence- and microscopybased OiW monitoring technologies for advanced Produced Water Treatment (PWT) control and evaluation, particularly by focusing on the de-oiling hydrocyclone installations.
The problem of marine litter represents a significant global challenge and illustrates the harmful consequences of an economic model that is based on disposability. The seafood sector is not only among the culprits, but is also among the most affected by this threat to the marine environment. Earlier research has pointed to fishing gear take-back schemes as a measure to mitigate the problem, and policymakers have embraced the idea. The Norwegian scheme for beverage containers has been hailed as a benchmark for the application of Extended Producer Responsibility. Through the lens of business ecosystems, we draw parallels between the existing take-back scheme for beverage containers and the latent system for fishing gear to answer the question: “What would it take to establish a take-back scheme for fishing gear?” We elaborate upon four factors that are well established for beverage container take-back schemes, but lacking or unclear in the case of fishing gear: (i) politico-institutional support, (ii) the system's value proposition, (iii) the system integrator, and (iv) operational factors (i.e., a network of collection points and procedures, and material variety and complexity). Our findings highlight that when innovations are not based on the usual market mechanisms, unconventional conceptualizations of value itself and how value is mapped and distributed are required. Meaningful engagement of the private sector depends upon either explicit articulation of value capture or policy instruments to enforce responsibility; both are currently either unclear or lacking in the context of fishing gear.
The capacity to act as a port state in international law is best described by the specific powers exercised over foreign ships, namely inspection, detention, expulsion or request of any type of information prior to the entry into the port. Many of these powers are explicitly attributed to the state in multilateral instruments, whereby the flag state consents to having its ships subject to the jurisdiction of the port state. Notwithstanding the consensus around the complementary nature of port state jurisdiction with respect to certain obligations of the flag state, the port state is not limited to fulfilling a secondary role. This is especially visible in the prevention, reduction and control of ship-source pollution, where some port states have not hesitated in acting regardless of an expressed consent by the flag state to the rule or standard being applied with the support of port powers. Not only do port states use more stringent enforcement powers to ensure that international treaties are effective, but they also prescribe novel rules and standards upon any foreign ship that approaches the port, often as a means of breaking an international negotiation deadlock. This study discusses the international legal basis for such unilateral jurisdiction by analyzing the principles of state jurisdiction under the dichotomy parochial/cosmopolitan. By interpreting the stated and implicit purposes of port state actions under that dichotomy, this study proposes that states are finding a legal ground to act based on certain legal functions they fulfill in the international legal order. This argument puts into perspective the assumed self-sufficiency of territoriality and shows how unilateralism may also serve to seek to set universally applicable norms.
The offshore de-oiling process is a vital part of current oil recovery, as it separates the profitable oil from water and ensures that the discharged water contains as little of the polluting oil as possible. With the passage of time, there is an increase in the water fraction in reservoirs that adds to the strain put on these facilities, and thus larger quantities of oil are being discharged into the oceans, which has in many studies been linked to negative effects on marine life. In many cases, such installations are controlled using non-cooperative single objective controllers which are inefficient in handling fluctuating inflows or complicated operating conditions. This work introduces a model-based robust H ∞ control solution that handles the entire de-oiling system and improves the system’s robustness towards fluctuating flow thereby improving the oil recovery and reducing the environmental impacts of the discharge. The robust H ∞ control solution was compared to a benchmark Proportional-Integral-Derivative (PID) control solution and evaluated through simulation and experiments performed on a pilot plant. This study found that the robust H ∞ control solution greatly improved the performance of the de-oiling process.
There has been a continued increase in the load on the current offshore oil and gas de-oiling systems that generally consist of three-phase gravity separators and de-oiling hydrocyclones. Current feedback control of the de-oiling systems is not done based on de-oiling efficiency, mainly due to lack of real-time monitoring of oil-in-water concentration, and instead relies on an indirect method using pressure drop ratio control. This study utilizes a direct method where a real-time fluorescence-based instrument was used to measure the transient efficiency of a hydrocyclone combined with an upstream gravity separator. Two control strategies, a conventional PID control structure and an H ∞ robust control structure, both using conventional feedback signals were implemented, and their efficiency was tested during severely fluctuating flow rates. The results show that the direct method can measure the system's efficiency in real time. It was found that the efficiency of the system can be misleading, as fluctuations in the feed flow affect the inlet concentration more than the outlet oil concentration, which can lead to a discharge of large oil quantities into the ocean.
An increasing water to oil ration in the North Sea oil and gas production motivates for an optimization of the current deoiling facilities. Current facilities are operated on matured methodologies, which in most cases fulfill the government regulations. However, it has also observed that these solutions could be further improved. In order to more precisely monitor the deoiling operations, this study investigated the real-time monitoring of the deoiling efficiency of the hydrocyclone facilities which are commonly used in offshore oil and gas production. Fluorescence based monitors were applied to measure hydrocyclone inlet's and underflow's Oil-in-Water (OiW) concentrations in real-time. Image-based microscopy was used to analyze the oil droplet size distribution at inlet and underflow to investigate the droplets' influence on hydrocyclone's efficiency. Performance experiments were carried out to identify how pressure difference ratio (PDR) and the droplet's sizes affect the deoiling efficiency. The performance of the deoiling hydrocyclone was significantly influenced by the inlet flow rate, while less or marginally dependent on the PDR. The droplet size distribution experiment proved that large droplets have a high probability to be separated by the hydrocyclone. The findings suggest that the coupled separator tank and hydrocyclone system can be further improved upon by deploying coordinated control as the two systems are strongly interdependent.
This article is a feasibility study on using fluorescence-based oil-in-water (OiW) monitors for on-line dynamic efficiency measurement of a deoiling hydrocyclone. Dynamic measurements are crucial in the design and validation of dynamic models of the hydrocyclones, and to our knowledge, no dynamic OiW analysis of hydrocyclones has been carried out. Previous studies have extensively studied the steady state efficiency perspective of hydrocyclones, and have related them to different key parameters, such as the pressure drop ratio (PDR), inlet flow rate, and the flow spill. Through our study, we were able to measure the dynamics of the hydrocyclone's efficiency (ϵ) response to step changes in the inlet flow rate with high accuracy. This is a breakthrough in the modelling, control, and monitoring of hydrocyclones.
Taking offspring in a problem of ship emission reduction by exhaust gas recirculation control for large diesel engines, an underlying generic estimation challenge is formulated as a problem of joint state and parameter estimation for a class of multiple-input single-output Hammerstein systems with first-order dynamics, sensor delay, and a bounded time-varying parameter in the nonlinear part. This brief suggests a novel scheme for this estimation problem that guarantees exponential convergence to an interval that depends on the sensitivity of the system. The system is allowed to be nonlinear, parameterized, and time dependent, which are characteristics of the industrial problem we study. The approach requires the input nonlinearity to be a sector nonlinearity in the time-varying parameter. Salient features of the approach include simplicity of design and implementation. The efficacy of the adaptive observer is shown on simulated cases, on tests with a large diesel engine on test bed, and on tests with a container vessel.
The goal of this paper is to introduce and design a cost-effective Oil-in-Water (OiW) measuring instrument, which will be investigated for its value in increasing the efficiency of a deoiling hydrocyclone. The technique investigated is based on Electrical Resistivity Tomography (ERT), whose basic principle is to measure the resistivity of substances from multiple electrodes and from these measurements create a 2-D image of the oil and gas component in the water. This technique requires the measured components to have different electrical resistances, such as seawater which has a lower electrical resistance than hydrocarbon oil and gas. This work involves construction of a pilot plant, for testing the feasibility of ERT for OiW measurements, and further exploring if this measured signal can be applied as a reliable feedback signal in optimization of the hydrocyclone's efficiency. Different algorithms for creating 2-D images and the feasibility of estimating OiW concentrations are studied and evaluated. From both steady state and continuous laminate flow perspectives, with respect to the objective which is to use this measurement for feedback control purposes.